skip header skip banner skip navigation
skip content

T90-2 type N39 door with thick rebate

T90-2 type N39 door with thick rebate

T90-2 type N39 fire-resistant door with thick rebate - Double leaf, fire-resistant steel door with thick rebate
 
Double, full-leaf steel doors, fire-resistant in accordance with DIN 4102, with door closer. Door leaf and frame galvanized and primed (powder-coated in RAL 9016)


Hardware

Type N39 from CS 2500 x 2500 mm standard fitted with 3 hinges on each leaf
Frames
Standard: Corner frame with sealing profile, counterframe, wrap-around or block frame or frame for butt wall connection optionally available
Sills
Standard: A floor level; B1, B2, B3 with four-sided continuous frame or C with lower rebate or RS1 sealing sills with lowerable floor seal optionally available
Surfaces
Door leaf and frame galvanized and primed (powder-coated in RAL 9016)




The following can also be supplied on request

  • Smoke protection nach DIN 18095
    in accordance with DIN 18095 (Type N39 tested with RS1 sill and centre rebate seal)
  • Soundproof
    32 dB, tested to DIN EN ISO 140-3, evaluated in accordance with DIN EN ISO 717-1 (laboratory value for full-leaf, RS1 sill and centre rebate seal)


Horizontal section

Horizontal section

Vertical section

Vertical section

 


Technical data
Model: T90-2 N39 door  
 

   
  Resistance class / Type Designation    
Approved dimensions Coordinating size (CS)
Min./Max. width
1375 - 3000
    Min./Max. height
1750 - 3000
  with top panel Max. height
  of which: Door Max. height
  Smoke protection with top panel Max. CS
       
Door leaf Approx. leaf thickness   68
  Approx. sheet thickness up to CS
2500 x 2500
 1,5
  Active leaf Min./Max. width
727 - 1477
  Inactive leaf
Min./Max. width 
500 - 1477
  Type of opening    according to DIN Left or right
       
Walls Masonry
≥ 240
  Concrete   ≥ 140
  Foam mortar block / precision blocks
≥ 240
  Reinforced foam mortar boards

≥ 200
  F90 walls made of gypsum plaster-boards (in accordance with DIN 4102 part 4, table 48), please consult us about other walls

On request
   
 
 
Versions 
Fire-resistant in accordance with DIN 4102   +
  With fire-resistant glazing  
  With additional top panel  
  With additional smoke protection   +
  With additional soundproofing   +
  With additional burglar resistance  
  Also available in stainless steel  
       
F90 glazing Standard rectangular types of glazing with glazing profiles made of steel or, optionally, aluminium or stainless steel CS 2500 x 2500 or more pedestal moulding height ≥ 625 needed   
   
  Standard round types of glazing with glazing profiles made of steel or, optionally, stainless steel + A9
 
  Special optional glazing, 124 x 124 to 755 x 1728, also available as multi-pane glazing, frieze widths ≥ 237 with glazing profiles made of steel or, optionally, aluminium or stainless steel  
       
  Registration number   Z-6.20-1987
       

+ possible | – not possible
   
All dimensions indicated in mm
CS = Coordinating size
OFD = Outer frame dimensions
CP = Clear passage dimensions




Standard sizes: T90-2 type N39 fire-resistant door with thick rebate, double leaf




Coordinating sizes
(order sizes)
Nominal sizes
(see below for calculation details)
Clear passage dimensions
(see below for calculation details)
Outer frame dimensions
(see below for calculation details)
1500 x 2000*** 1510 x 2005 1420 x 1960 1582 x 2061
1500 x 2125*** 1510 x 2130 1420 x 2085 1582 x 2186
1750 x 2000**** 1760 x 2005 1670 x 1960 1832 x 2061
1750 x 2125**** 1760 x 2130 1670 x 2085 1832 x 2186
2000 x 2000 2010 x 2005 1920 x 1960 2082 x 2061
2000 x 2125 2010 x 2130 1920 x 2085 2082 x 2186
2000 x 2500 2010 x 2505 1920 x 2460 2082 x 2561
2125 x 2125 2135 x 2130 2045 x 2085 2207 x 2186
2250 x 2250 2260 x 2255 2170 x 2210 2332 x 2311
2500 x 2500 2510 x 2505 2420 x 2460 2582 x 2561
       

Outer frame dimensions incl. 20 mm floor recess.
***) Leaf division (instead of 1/2 : 1/2) approx. 1/3 : 2/3, active leaf CS 956
****) Leaf division (instead of 1/2 : 1/2) approx. 1/3 : 2/3, active leaf CS 978
    
All dimensions indicated in mm, CS = Coordinating size, OFD = Outer frame dimensions, CP = Clear passage dimensions




Calculation of clear passage and outer frame dimensions (not for T90-2 type N39)



Documented heat insulation

Documented heat insulation

Smokeproof acc. to DIN 18095

Smokeproof acc. to DIN 18095

Soundproof in accordance with DIN EN ISO 140-3

Soundproof in accordance with DIN EN ISO 140-3

 


Further information is available in PDF format here:

  • Frames for T30 and T90 fire-resistant doors and steel multi-purpose doors.
    Download PDF file
     
  • Frame mounting hardware for T30 and T90 fire-resistant doors
    and steel multi-purpose doors.
    Download PDF file
      
  • Sills, anchor plans for T30 and T90 fire-resistant doors and
    steel multi-purpose doors.
    Download PDF file

skip teaser

Installation advantages

Montagevorteile

 

Online catalogues

Online catalogues

 

Advice & Contact

Advice & Contact

 
 
Go to top

You might be interested in these topics as well