T30-1 type N2/50 wall flap with thick rebate

T30-1 type N2/50 wall flap with thick rebate
Single, full-leaf steel doors, fire-retardant in accordance with DIN 4102, with door closer (depending on the model). Door leaf and frame galvanized and primed (powder-coated in RAL 9016).
Hardware
(If standard hardware is used on types N2/50, the profile cylinder must be lengthened by 0/10 mm).
Frames
Standard: Corner frame with sealing profile, optional counterframe. Wrap-around or block frames or frames for butt wall connections are optionally available for types N2/50, as is a block frame in front of the wall.
Sills
N2/50 flap: Standard B1; B2, B3, RS1 or RS2 optional.
Surfaces
Door leaf and frame galvanized and primed (powder-coated in RAL 9016).
The following can also be supplied on request
- Fire-resistant glazing
- Top panel
- Smoke protection in accordance with DIN 18095
- Soundproof
- (not the version with top panel) type N2/50 flap: 42-45 dB,
tested to DIN EN ISO 140-3, evaluated in accordance with
DIN EN ISO 717-1 (laboratory value for full-leaf and B1 or B2 sill) - Burglar-resistant
- (not for models with top panel) tested on both sides to
DIN ENV 1627 WK2 N2/50 flap: only for floor recess up to ≥ 20 mm.
(Burglar resistance for N2/50 doors not permitted for F90 walls made
of gypsum plasterboard or foam mortar) - In stainless steel

Horizontal section

Vertical section
Door closer needed for model with smoke protection or models installed in walls made of foam mortar or gypsum plasterboard.
| Model | T30-1 N2 / 50 wall flap |
|
|
| Resistance class / Type Designation |
|||
| Approved dimensions | Coordinating size (CS) |
Min/Max width |
500 - 1250 |
| Min/Max heigh. |
500 - 1250 |
||
| with top panel | Max. height |
– | |
| of which: Door | Höhe max. |
– | |
| Smoke protection with top panel | Max. height | – |
|
| Door leaf | Approx. leaf thickness | 53 | |
| Approx. sheet thickness |
up to CS 500 x 1750 | 1.0 (optionally 1.5) | |
| Active leaf | – | ||
| Inactive leaf | – | ||
| Type of opening | according to DIN | Left or right | |
| Walls | Masonry | ≥ 115 | |
| Concrete | ≥ 100 | ||
| Foam mortar block / precision blocks | ≥ 115 | ||
| Reinforced foam mortar wall panels | ≥ 100 | ||
| F90 walls made of gypsum plaster-boards (in accordance with DIN 4102 part 4, table 48), please consult us about other walls | ≥ 100 | ||
| Versions |
Fire-retardant in accordance with DIN 4102 | + | |
| With fire-resistant glazing | – | ||
| With additional top panel | – | ||
| With additional smoke protection | + | ||
| With additional soundproofing | + | ||
| With additional burglar resistance | + | ||
| In stainless steel | + | ||
| F30 types of glazing |
Rechteckige Standard rectangular types of glazing with glazing profiles made of steel or, optionally, aluminium or stainless steel CS 2500 x 2500 or more pedestal moulding height > 625 needed | – | |
| Standard round types of glazing with glazing profiles made of steel or, optionally, stainless steel | – | ||
| Special optional glazing, 150 x 150 to 913 x 1921, also available as multi-pane glazing, frieze widths > 155 with glazing profiles made of steel or, optionally, aluminium or stainless steel (wall flap: min. CS 625 x 625 mm) | – | ||
| Registration number | Z-6.20-2016 |
All dimensions indicated in mm,
CS = Coordinating size,
OFD = Outer frame dimensions,
CP = Clear passage dimensions
Standard sizes:
T30-1 type N2/50 fire-resistant door - wall flap with thick rebate, single leaf
| Coordinating sizes (order sizes) |
Nominal sizes (see below for calculation details) |
Clear passage dimensions (see below for calculation details) |
Outer frame dimensions (see below for calculation details) |
| 750 x 750 | 760 x 760 | 670 x 670 | 832 x 832 |
| 750 x 875 | 760 x 885 | 670 x 795 | 832 x 957 |
| 800 x 800 | 810 x 810 | 720 x 720 | 882 x 882 |
| 875 x 875 | 885 x 885 | 795 x 795 | 957 x 957 |
| 875 x 1000 | 885 x 1010 | 795 x 920 | 957 x 1082 |
| 875 x 1250 | 885 x 1260 | 795 x 1170 | 957 x 1332 |
| 1000 x 1000 | 1010 x 1010 | 920 x 920 | 1082 x 1082 |
| 1000 x 1250 | 1010 x 1260 | 920 x 1170 | 1082 x 1332 |
| 1250 x 1250 | 1260 x 1260 | 1170 x 1170 | 1332 x 1332 |
All dimensions indicated in mm,
CS = Coordinating size,
OFD = Outer frame dimensions,
CP = Clear passage dimensions
Calculation of clear passage and outer frame dimensions
(not for T90-2 type N39)
Fire-retardant in accordance with DIN 4102
Smokeproof acc. to DIN 18095
Documented heat insulation
Soundproof in accordance with DIN EN ISO 140-3
Burglar resistant in accordance with DIN V ENV 1627
Further information is available in PDF format here:
- Frames for T30 and T90 fire-resistant doors and steel multi-purpose doors.
Download PDF file
- Frame mounting hardware for T30 and T90 fire-resistant doors and
steel multi-purpose doors.
Download PDF file
- Sills, anchor plans for T30 and T90 fire-resistant doors and
steel multi-purpose doors.
Download PDF file