T30-1 type N2/50 door with thick rebate

T30-1 type N2/50 door with thick rebate
Single, full-leaf steel doors, fire-retardant in accordance with DIN 4102, with door closer (depending on the model). Door leaf and frame galvanized and primed (powder-coated in RAL 9016).
Hardware
(If standard hardware is used on type N2/50, the profile cylinder must be lengthened by 0/10 mm).
Frames
Standard: Corner frame with sealing profile, optional counterframe Wrap-around or block frames or frames for butt wall connections are optionally available for type N2/50, as is a block frame in front of the wall.
Sills
N2/50 door: Standard A; B1, B2, B3 and RS1 or RS2 optional, and sill C with lower rebate.
Surfaces
Door leaf and frame galvanized and primed (powder-coated in RAL 9016).
The following can also be supplied on request
- Fire-resistant glazing
- Top panel
- Smoke protection in accordance with DIN 18095
- Soundproof
(not the version with top panel) type N2/50 door: 34 dB, tested to DIN EN ISO 140-3, evaluated in accordance with DIN EN ISO 717-1 (laboratory value for full-leaf and RS1 sill on door) - Burglar-resistant
(not for models with top panel) tested on both sides to DIN ENV 1627 WK2 N2/50 door: only for floor recess up to ≥ 20 mm. (Burglar resistance for N2/50 doors not permitted for F90 walls made of gypsum plasterboard or foam mortar) - In stainless steel

Horizontal section

Vertical section
Door closer needed for 1.5 mm sheet thickness and CS > 1000 x 2125 mm or when installed in walls made of foam mortar or gypsum plasterboard or for smoke protection in accordance with DIN 18095.

Vertical section, top panel (optionally also available with glazing)
| Model: | T30-1 N2 / 50 door | |
|
| Resistance class / Type Designation |
|||
| Approved dimensions | Coordinating size (CS) |
Min/Max width |
625 - 1350 |
| Min/Max height |
1500 - 2500 |
||
| with top panel | Max height |
3500 | |
| of which: Door | Max height |
2450 | |
| Smoke protection with top panel | Max. CS | 3000 |
|
| Door leaf | Approx. leaf thickness | 53 | |
| Approx. sheet thickness |
up to CS 500 x 1750 | 1.0 (optionally 1.5) | |
| Active leaf | – | ||
| Inactive leaf | – | ||
| Type of opening | according to DIN | Left or right | |
| Walls | Masonry | ≥ 115 | |
| Concrete | ≥ 100 | ||
| Foam mortar block / precision blocks | ≥ 115 | ||
| Reinforced foam mortar wall panels | ≥ 100 | ||
| F90 walls made of gypsum plaster-boards (in accordance with DIN 4102 part 4, table 48), please consult us about other walls | ≥ 100 | ||
| Versions |
Fire-retardant in accordance with DIN 4102 | + | |
| With fire-resistant glazing | + | ||
| With additional top panel | + | ||
| With additional smoke protection | + | ||
| With additional soundproofing | + | ||
| With additional burglar resistance | + | ||
| In stainless steel | + | ||
| F30 types of glazing | Standard rectangular types of glazing with glazing profiles made of steel or, optionally, aluminium or stainless steel CS 2500 x 2500 or more pedestal moulding height > 625 needed | ||
| Standard round types of glazing with glazing profiles made of steel or, optionally, stainless steel | |||
| Special optional glazing, 150 x 150 to 913 x 1921, also available as multi-pane glazing, frieze widths ≥ 155 with glazing profiles made of steel or, optionally, aluminium or stainless steel |
|||
| Registration number |
Z-6.12-1482 | ||
All dimensions indicated in mm
CS = Coordinating size
OFD = Outer frame dimensions
CP = Clear passage dimensions
Standard sizes:
T30-1 type N2/50 fire-resistant door - door with thick rebate, single leaf.
| Coordinating sizes (order sizes) |
Nominal sizes (see below for calculation details) | Clear passage dimensions (see below for calculation details) |
Outer frame dimensions (see below for calculation details) |
| 750 x 2000 | 760 x 2005 | 670 x 1959 | 832 x 2060 |
| 750 x 2125 | 760 x 2130 | 670 x 2084 | 832 x 2185 |
| 875 x 1875 | 885 x 1880 | 795 x 1834 | 957 x 1935 |
| 875 x 2000 | 885 x 2005 | 795 x 1959 | 957 x 2060 |
| 875 x 2125 | 885 x 2130 | 795 x 2084 | 957 x 2185 |
| 1000 x 2000 | 1010 x 2005 |
920 x 1959 | 1082 x 2060 |
| 1000 x 2125 | 1010 x 2130 | 920 x 2084 | 1082 x 2185 |
| 1125 x 2000 | 1135 x 2005 | 1045 x 1959 | 1207 x 2060 |
| 1125 x 2125 | 1135 x 2130 | 1045 x 2084 | 1207 x 2185 |
| 1250 x 2000 |
1260 x 2005 | 1170 x 1959 |
1332 x 2060 |
| 1250 x 2125 |
1260 x 2130 | 1170 x 2084 | 1332 x 2185 |
| 1250 x 2250 | 1260 x 2255 | 1170 x 2209 | 1332 x 2310 |
| 1250 x 2500 | 1260 x 2505 | 1170 x 2459 |
1332 x 2560 |
All dimensions indicated in mm
CS = Coordinating size
OFD = Outer frame dimensions,
CP = Clear passage dimensions
Calculation
of clear passage and outer frame dimensions (not for T90-2 type N39)
Fire-retardant in accordance with DIN 4102
Smokeproof acc. to DIN 18095
Documented heat insulation
Soundproof in accordance with DIN EN ISO 140-3
Burglar resistant in accordance with DIN V ENV 1627
Further information is available in PDF format here:
- Frames for T30 and T90 fire-resistant doors and steel multi-purpose doors
Download PDF file
- Frame mounting hardware for T30 and T90 fire-resistant doors and
steel multi-purpose doorsl.
Download PDF file
- Sills, anchor plans for T30 and T90 fire-resistant doors and
steel multi-purpose doors.
Download PDF file