Rd SKE 2 smokeproof sliding door

Rd SKE 2 smokeproof sliding door

Characteristics

  • Double leaf
  • Full leaf in modular element design
  • Leaf and frame profiles galvanized
  • General building code test certificates
    - P-BWU 03-I 17.67.17 for double leaf T30 version
    - P-BWU 03-I 17.67.34 for double leaf T90 version



Versions

  • Smokeproof in accordance with DIN 18095 Part 3
  • With door ingoing brake (radial damper)
  • Also available with hold-open system
  • Also available for low headers, with optional inlet and/or header panel
  • Also available with activation aids
  • Also available with panel field glazing
    Standard pane size 270 x 630 mm,
    special pane sizes up to 450 x 1100 mm (longer lead times),
    requisite frieze width per panel field 190 mm on three sides,
    pedestal height 1150 mm.
  • Also available with smokeproof pass door
    (for single leaf doors only, can be combined with T30 or T90 fire protection)
    Smallest dimensions with pass door 1675 x 2100 mm CP
  • Also available with T30 or T90 in accordance with DIN 4102
    (see previous double page)

Description


Approved dimensions

Height: max. 4500 mm
Width: max. 7000 mm
Single leaf doors up to approx. 25 m² CP
Single leaf doors with movable central joint up to approx. 15 m²
Double leaf doors up to approx. 15 m² CP
  • Sliding door leaves up to 1500 mm in width must not be
    higher than max. 2500 mm (CP in each case).

Door leaf

Thickness: approx. 67 mm
Sheet metal: 1 mm
Weight: approx. 55 kg/m²
  
Door leaf must overlap the clear opening:
by ≥ 70 mm at the sides
with T30 ≥ 100 mm
with T90 ≥ 150 mm by ≥ 75 mm at the header
(by ≥ 85 mm in the case of low headers)

Note: The upper horizontal smoke seal protrudes about 30 mm into the clear passage.

Storage area for opened door

= Clear opening width + 350 mm
   (plus additional 150 mm for low headers with closing weight an inlet)
  
Necessary header height (mm) for

normal header/wall installation ≥ 220
low header/ceiling installation ≥ 125

Wall clearance

≥ 200 mm

Sill for opening and storage area

recessed or surface mounted on the floor, or optionally without if the site has been prepared accordingly.
  • On-site preparation if the sill is recessed in the floor. Floor sill is set with sill brackets, aligned and filled (on-site) prior to installation of the door.
  • Evenness tolerance for finished floors with mounted sill in the opening and storage area in accordance with DIN 18202, Table 3, Line 4.
  • A floor sill is not necessary if the floor is smooth and even, and without joints in the opening and storage area.


Additional features

Smokeproof pass door 1000 x 2000 mm without sill, for single leaf smokeproof sliding doors only (Rd SKE 1), can be combined with T30 or T90 fire protection. Smallest dimensions with pass door 1675 x 2100 mm CP.
     
Activation aids and special features on request

Activation aids and special features on request

Activation aids and
special features on request

Activation aids and special features on request

Activation aids and
special features on request

 

Clear passage width

Clear passage width

 


(*)
door without pass door 200 mm
door with pass door 250 mm
door with bag flap 280 mm

All dimensions in mm

CP = Clear passage dimensions
UEFF = Upper-edge finished floor