skip header skip banner skip navigation
skip content

Innovative solutions for fire protection installations in dry mortarless construction

Innovative solutions for fire protection installations in dry mortarless construction

For approved F90 mounting walls
Novoferm offers innovative solutions for installing frames in lightweight construction stud walls, e.g. concealed screw assembly for a flawless appearance of a T30 fire-resistant door. T90 fire-resistant doors can be quickly and easily installed in approved F90 stud walls that are at least 100 mm thick – and are available for a wide range of different wall systems.
         
      
Installation solutions specifically for dry mortarless construction.


Concealed mounting of T30

Concealed mounting of T30. An innovative solution specifically for dry mortarless construction. Concealed screw assembly of T30 doors in lightweight fire-resistant stud walls.
  
  
   
Wall thicknesses

The new installation technique developed by Novoferm can be used for the following standard wall thicknesses: 100, 125 and 150 mm.
Door types
Fire-resistant doors
:
T30-1 N2/50
T30-2 N22/50
Multi-purpose doors:
MZ 53-1
MZ 53-2
  
The advantages at a glance:

  • Flawless door appearance thanks to new concealed mounting t
    echnique for all mounting walls specified in DIN 4102, part 4, table 48
  • Not a single visible screw on the frame facing
  • Installation requires no more effort than conventional frames
  • Ideal for installation in existing walls

    T90 installation in wall thicknesses of just 100 mm or more

    T90 installation in wall thicknesses of just 100 mm or more
    Benefits also apply to T90 doors installed in lightweight fire-resistant stud walls. You can now extend the range of applications for T90 fire-resistant doors.
      
     
      
    Bare shell dimensions

    The registration covers any dimensions between 500 x 500 mm and 2500 x 2500 mm.
    Door types
    T90-1 N9
    T90-1 N19
    T90-2 N29
      
    The advantages at a glance:

    • Approved for DIN mounting walls of just 100 mm or more
    • Also approved for virtually all other F90 mounting wall systems,
      in addition to the mounting walls specified in DIN 4102, Part 4, Table 48
    • Door jamb made of square tubing
    100 mm wall thickness min. 50 x 50 x 4 mm
    125 mm wall thickness min. 75 x 50 x 4 mm
    150 mm wall thickness min. 100 x 50 x 4 mm