Frame back-filling with fire protection foam for T30 doors

Fast and clean frame installation in metal construction ...
Our extended range of frames enhances the benefits of using the Novoferm installation system for metal construction companies even further.
Choose the perfect frame to match your property from the approved frames and types of installation and add Novoferm fire protection foam for back-filling.
Nowadays, there is now easier, cleaner and faster way to assemble fire-resistant doors.
Corner frame
with sealing profile
Choose whichever of the three installation methods you prefer:
- Welding
- Bolting
- Dowelling
Registration Z-6.20.2016
Corner frame with counterframe
Corner frame with sealing profile
Choose whichever of the three installation methods you prefer:
- Welding
- Bolting
- Dowelling
Note: The counterframe can be left empty or filled, just as you like.
Registration Z-6.20.2016
Wrap-around frame
Wrap-around frame
with sealing profile
Choose whichever of the three installation methods you prefer*:
- Welding
- Bolting
* for all opening widths
Registration Z-6.20.2016
Corner frame with counter frame
Corner frame with counter frame
Corner frame with sealing profile
Approved installation methods::
- Conventional bolting
- Concealed Novoferm threaded joints for a flawless appearance
- Corner frame can remain empty
Registration Z-6.20.2016

Why opt for fire protection foam from Novoferm?
The door leaf, frame and special fire protection foam from Novoferm have been tested and approved by the construction supervisory authority as a single unit.
Facts ...
- Fire protection foam for frame back-filling on doors with corner frame
- Size range: single leaf up to 1350 x 2500 mm,
double leaf up to 3000 x 3000 mm - Corresponds to door types: T30-1 N2/50 and T30-2 N22/50
- For installation in masonry/concrete, by bolting, dowelling and welding
- Tested in accordance with the criteria of EN 1634-1,
approved in accordance with DIN 4102-5
Frames can be back filled much more quickly and cleanly with the fire protection foam from Novoferm than with mortar. The usual prior knowledge for installing fire-resistant doors is completely adequate. The documentation of registration-compliant installation is unbelievably simple. Self-adhesive labels on the can of foam contain all the necessary information. They can be easily removed and are simply stuck onto the confirmation of conformity.
Application

Once the frame has been inserted, spray the area between the frame and the wall with water. This makes the foam expand even more effectively.

Then fill the cavity entirely with fire protection foam and leave to dry for at least 30 minutes.

Use a sharp knife or cutter to remove any protruding foam.

The transition from frame to wall (on the opposite side of the hinge) can be cleanly covered with a self-adhesive plastic profile with soft lip, which can then be painted over (available at additional cost).

That is all you need: