skip header skip banner skip navigation
skip content

Fire-resistant doors and flaps

Fire-resistant doors

T30 / T90 fire-resistant doors – inspiringly good
As a specialist for steel doors, Novoferm offers a wide range of fire-resistant doors that are all approved to general building code standards. Whether T30 or T90, standard version or version with top quality special finish - you will find the perfect solution for practically any application here. Our fire-resistant doors are all fully galvanized and primed. The galvanized and additionally powder-coated corner frames with sealing profile are also standard. Other frame or sill solutions are available to meet the respective statutory requirements. The attractive design of the door is rounded off by a wide choice of ergonomically designed hardware.


Fire-resistant doors

Standard means more than just “from the rack“
You can choose just the right fire-resistant doors to match your property from our wide range of available designs, sizes and finishes. We can also provide matching seals for various special applications – just tell us what you need and we will find the solution.


NovoFire® Vario 50

Frame back-filled with loose mineral wool – perfect for modern interior fittings
NovoFire® Vario 50 T30 doors are attractive, with impressive features that include standard 3-D hinge and thick rebate. Back-filled with loose mineral wool, they are now also building code approved for F60 and F90 installation walls ...
more



T30 NovoFire® Vario 50

T30 NovoFire® Vario 50

T30 NovoFire® Vario 50 double leaf

T30 NovoFire® Vario 50
double leaf

T30-1 Typ H8-5

T30-1 Typ H8-5
door with thin rebate

 

T30-1 Typ N2/50

T30-1 Typ N2/50 wall flap with thick rebate

T30-1 Typ N2/50

T30-1 Typ N2/50
door with thick rebate

T30-2 Typ N22/50

T30-2 Typ N22/50
door with thick rebate

 

T30-2 Typ N22/50

T30-2 Typ N22/50
door with thick rebate

T30-2 Typ N22

T30-2 Typ N22
door with thick rebate

T90-1 Typ N9

T90-1 Typ N9
wall flap with thick rebate

 

T30-2 Typ N22

T30-2 Typ N22
door with thick rebate

T30-2 Typ N22

T30-2 Typ N22
door with thick rebate

T90-1 Typ N19

T90-1 Typ N19
door with thick rebate

 

T90-1 Typ N9

T90-1 Typ N9
wall flap with thick rebate

T90-1 Typ N19

T90-1 Typ N19
door with thick rebate

T90-2 Typ N29

T90-2 Typ N29
door with thick rebate

 

T90-2 Typ N29

T90-2 Typ N39
door with thick rebate

 
Fire-resistant doors

Standard design
Door leaf: made of galvanized, mechanically specially aligned thin sheets, with rebate on three sides, therefore with thick rebate to match the front door (type H8-5 thin rebate), together with fire protection insulation.
 
Heat insulation
In accordance with DIN 52619. Glazed doors with fire-resistant glass in line with statutory requirements for interior use.
  
Frame:
Galvanized, standard version as corner frame with EPDM sealing profile. Screw fastening with masonry dowels on all single-leaf doors with a width ≥ 1250 mm and on all double-leaf doors.
  
Hardware:
Three-section hinge plates with ball bearings, pins, door closer in accordance with DIN EN 1154 (T30-1 doors with ball bearing hinge plate and spring plate in accordance with DIN 18272, some with upper door closer, dependent on size, T90-1 doors always with upper door closer, optional spring plate up to 2m². Upper door closer for type H8-5 available at additional charge). DPC mortice lock with drawback latch, with black rounded handle set (turn-lock mounted). Two-leaf doors with two upper door closers and additional automatic retracting bolt with handle for the inactive leaf and lock coordinator (T30-2 doors type N22/50 with rebate retracting bolt).
   
Surface:
made of galvanized steel, primed (with environmentally friendly powder-coating in RAL 9016, traffic white).


Multi-purpose steel doors

The right design to meet any standard
Our N series of fire-resistant doors is particularly suited for sophisticated properties. The elaborate finish, the design, which is even suitable for living areas, and the versatile range of special finishes make them the door of choice for demanding property developers.


Fire-resistant doors

Special design
Other frame models instead of the standard frame. Only a 1.5 mm counterframe can be optionally used on T30-1 type H8-5).
Special sill design. Fixed upper section on various types of T30. Sealing profile between the frame and top panel and between the leaves. Other hardware that complies with the statutory requirements for fire-resistant doors is optionally available, such as handles, slide channel door closers (with integrated lock coordinator on two-leaf doors), panic locks.
 
ITS96 door closer system integrated into the leaf (T30-1 type N2/50 and T30-2 type N22/50 only, full leaf or glazed in each case).
Electric door opener, monitor contacts or locks, hold-open systems, and much more. T30 and T90 fire-resistant glazing with UV protection on one side for areas exposed to direct sunlight.
Door leaf and frame made of stainless steel V2A - 1.4301 or V4A - 1.4571.




The right glazing in case of fire
Novoferm offers fire-resistant doors with numerous types of standard-compliant glazing. Not only are special types of glazing available, the doors can also be supplied with optional individual window cutouts. Please let us know your requirements.




Glazing
Although Novoferm generally supplies its multi-purpose and fire-resistant doors with various types of standard-compliant glazing, a wide range of special glazing options are also available.
Standard-compliant glazing comes in a choice of different cutout sizes and shapes - rectangular, round or rhombus-shaped. Wire laminated or VSG laminated glass is available, as are several types of ISO glazing up to 19 mm thick.
Anyone considering one of the rectangular types of special glazing can choose from seven different types of glass. The shape and size of the window cutout can be designed with great flexibility. Your best bet is to talk to us directly



Fire-resistant doors
Fire-resistant doors
Fire-resistant doors
 


Technical description
Definition:
The purpose of self-closing fire-resistant doors is to prevent fire from penetrating wall openings when installed.
Approval:
Our fire-resistant seals have been officially tested in accordance with DIN 4102 and have been awarded general building code approval by means of certification issued by the Deutsches Institut für Bautechnik, Berlin.
Quality surveillance:
Compliance with the seal requirements defined in the approval certification is monitored by a recognized quality protection association. To prove this, each fire-resistant seal has an embossed plate indicating the mark with information on design, registration number, quality protection association, manufacturer and year of manufacturer.
Installation:
Both the wall in which the fire-protection seal is to be installed and the fastening of the frame must comply with the approval requirements.



Fire-retardant in accordance with DIN 4102

Fire-retardant in accordance with DIN 4102

Smokeproof acc. to DIN 18095

Smokeproof acc. to DIN 18095

Documented heat insulation

Documented heat insulation

 

Soundproof in accordance with DIN EN ISO 140-3

Soundproof in accordance with DIN EN ISO 140-3

Tested security WK2

Burglar resistant in accordance with DIN V ENV 1627

 